rev120: 1. for STM32_CO2_RS485, add parity and dont reboot rev119: 1. only for PM2.5, show AQI level rev118: 1. only for CO2, leds indicate the range of CO2. 2. for CO2, float registers have conflict with old co2 registers. only keep FLOAT_ABCD type for special customer. rev117: 1. only for HUM, Add the float registers of the temperature and humidity rev116: 1. for CO2, fix HUM and Temp value jump between two sensors when SCD4X and SHT3X exist in older revision. rev115: 1. for HUM, resume reg450,451 for temperatue and humidty calibration. rev114: 1. for pressuer, fix the stack length of pressure task to avoid reboot. 2. avoid reboot caused by wifi transmit. 3. support changing vendor name 4. swap bacnet value of ao1 & ao2 rev113: 1. for HUM, cause reboot when no wifi module in last version. rev112: 1. for co2_d_x, avoid show setting T/H point rev111: 1. for mulit I2C sensor, basic test is ok rev110: 1. support flashing using MSTP protocal rev109: 1. for PM2.5,PRESSUE, dont need setpoint funciton rev108: 1. for CO2, fix register number of password acorrding to register list 2. update baclib, fix who-is command with range rev102: 1. change bigger stack rev101 1. avoid always reading EEP_SUB_PORT, read one time only when start-up. rev100: 1. fix output issue in rev99 rev99: 1. add AQ sensor 2. save wifi information 3. enable wifi flag in srceen rev98: 1. fix display if only tempertaure sensor, product =213, reg122 = 1 reg97: 1. for CO2, fix the issue cant fix humidy via t3000 rev96: 1. add uint for dewpoint, partial pressue,mixing ration,enthalpy Rev95 1. Add light sensor's value to bacnet AI rev94: 1. Fix humidity calibration cannot be changed on screen rev93: 1. Fixed temperature and humidity value still keep when sensor is offline 2. Added Tx and Rx icon on screen rev92:FOR HUM_RS485, fix position of buttons rev91: 1. fix calbiration of humidy 2. add calbirateion for light sensor rev89: 1. fix display F when tempreraute source is SCD40 rev88: 1. for co2, fixe AO of HUM channel when mode is MANUAL 2. show humdiy 10% correctly, show 0% in last verison rev87: 1. check all task to avoid task is locked. rev86: 1. fix temperature_Task locked in recent version. rev85: FOR HUM_RS485, ADD heartbeat LED rev83: For RTS rev82: modify AO range of PM2.5 and PRESSURE, it is changed by mistake since rev80. rev81:for CO2_NODE_RS485,add low_pri in key_task to avoid reboot by mistake rev80: change AO range of default temperature -40 to 60 rev79:change the stack of net _task bigger rev78: add new co2 sensor SCD40 rev77: adjust task stack for every task. rev75: 1. Disable WIFI, fixed button task locked in last revison. rev74: 1. fix CO2 locked rev73: Restore calculating humidity parameters, this feature has been incorrectly hidden in recent releases rev72: Fix modbus read long bytes when baudrate is 9600. rev71 1. initial ethenet chip if network task abnormal rev70 1. For CO2,if SNESOR is SCD30, get rid of filter rev69: 1. for wifi,add re-connect function if connection is interrupted. REV68 1. FOR HUM, fix value of AI0 REV67 1.For PM2.5, add temperature and humidity REV66 LCD backlight turn on time can be set REV65 Add the light icon rev64 modify the manual output part of PM2.5 REV63 The subnet_buf overflow caused a problem on output REV62 Modify the serial priority to avoid resetting when processing large amounts of data REV61 Modify the password Settings REV60 The ID is limited to 1-254 and saved to E2 rev59 Add register MAX_MASTER 29 rev58 Modify the display of PM2.5 for Wanger customer and add parity rev57 Make the MSTP send BUF larger to avoid MSTP send overflow rev56 Fixed buzzer issues, update BACNET library . rev55 add led status for node ,Show default value 0 when CO2 is not detected . rev54 Add WIFI and RSSI rev53 Clear the negative sign when displaying negative to positive numbers rev52 Save the IP address obtained by DHCP rev51 Compatible with two kinds of CO2 modules rev50 AQI index adds customer custom form. rev49 Fixed bugs of RTC, So that the device will not crash due to RTC broken. rev48 Fix the display problem of the third line after the scroll bar is closed.Fixed the problem of CO2 sensor recognition and the configuration of a reset pin.Changed the scroll bar of PM2.5 to display AQI instead of ALARM. rev47 Support PM2.5, Added AQI level of China and USA, register 126 for selection, 1 for China and 0 for USA. rev46 Added an option to enable/disable status scroll line , change menu. rev45 Added color LCD support, sensirion's CO2 sensor support, Add a range register 135 to the dot matrix screen PM25,Register 135 is set to 0, the range is 0-99ug / m3, register 135 is set to 1, the range is 0-999ug / m3.